Screen Droga Test superfici e polveri

Screen Drug Test Surfaces Powders

PHARMACIST CODE: 970791760 – RETAIL PRICE €. 24,00

Drug test that detects presence of drugs in surfaces, powders or solids. It detects the presence of 7 drugs: Amphetamine (AMP), Cocaine (COC), Marijuana (THC), Methamphetamine (MET), Methylenedioxymethamphetamine (MDMA), Morphine (MOP), Ketamine (KET). The result is specific to each substance analyzed.

Free-sale product not intended for medical purposes.

Benefits

  • Selective detection of 7 types of drugs on surfaces and solids
  • Rapid result for each type of drug analyzed
  • Can be performed without the use of instrumentation

How it is used on surfaces

  • Remove the panel cap and wipe with the panel on the surface where drugs are suspected to be present.

  • With the arrow pointing toward the water, immerse the test panel vertically in the water for at least 10-15 seconds. Dip the strips at least up to the level of the wavy lines, but not beyond the arrow on the test panel.

  • Wait for the colored lines to appear. The test result should be read after 5 minutes. Do not interpret the result after 10 minutes.

How it is used on solids

  • Prepare sample collection containers and solid sample.

  • For the solid sample in the sample collection containers.

  • At least 1 mg of solid diluted with 5 ml of water (1 bottle cap of mineral water≈5 ml). Shake to mix well.

  • Remove the panel cap with the arrow pointing toward the water immerse the test panel vertically in the water sample for at least 10-15 seconds. Dip the strips at least up to the level of the wavy lines, but not beyond the arrow on the test panel.

  • Wait for the colored lines to appear, read the results after 5 minutes and do not interpret them after 10 minutes.

How it is used with urine

  • Collect the urine in a clean, dry container.

  • Remove the panel cap and, with the arrow pointing toward the sample, dip the test panel vertically into the sample for at least 10-15 seconds. Dip the strips at least up to the level of the wavy lines, but not beyond the arrow on the test panel.

  • Wait for the colored lines to appear, read the results at 5 minutes and do not interpret them after 10 minutes.

How to use it with liquids

  • Prepare sample collection containers and liquid sample.

  • Pour one to three drops of suspected liquid into 5 mL of water (1 cap of mineral water≈5mL bottle). Shake to mix well.

  • Remove the panel cap and, with the arrow pointing toward the sample, dip the test panel vertically into the sample for at least 10-15 seconds. Dip the strips at least up to the level of the wavy lines, but not beyond the arrow on the test panel.

  • Wait for the colored lines to appear, read the results at 5 minutes and do not interpret them after 10 minutes.

Package Contents

  • N.1 Testing device

  • N.1 Package insert

  • Operating Instructions
  • Materials required but not provided

  • Sample collection container

  • Timer

Operating Instructions